Colocation & Data Center CHIL2

    Chicago, Illinois

    fifteenfortyseven CHIL2 Chicago Data Center & Colocation Facility

    Our Chicago, Illinois data center at 725 South Wells is specifically designed for businesses that demand abundant space, tight security and reliable redundancy. The nine-story, 42,000 sq. ft facility is located in one of the top data center markets in the United States, and offers robust connectivity to 350 Cermak Road. Positioned atop Chicago’s “Fiber Ring,” your business will have access to redundant connections from multiple providers.

    Why Chicago?
    • One of the top data center markets in the United States
    • Readily available access to trans-continental fiber networks
    • Situated in a fiber-rich, increasingly large cloud ecosystem
    • Favorable business climate
    • Access to international financial exchanges
    • Low risk for natural disasters
    1547 logo
    FACILITY HIGHLIGHTS
    • Located in a fiber-rich, Tier 1 data center market
    • Positioned atop Chicago’s “Fiber Ring”
    • 9 stories; 42,000 sq. ft. data center space
    • 18,000 sq. ft. ancillary / support / office space
    • Three separate fiber entrances and risers
    • Robust connectivity to 350 Cermak Road, Chicago’s largest and most interconnected data center
    • Multiple UPS plants and redundant distribution paths for maximum UPS backup capabilities
    • VESDA detection and FM200 INERGEN® Fire. Suppression System

    Chicago, Illinois Data Center Overview

    Download our CHIL2 Data Center Sell Sheet

    • Custom-built power, copper & fiber distribution
    • Custom-designed suites
    • 42,000 sq. ft data center space
    • 2,000 to 6,000 sq. ft suites
    • Hardwalled, and 12′ slab to slab dedicated suites
    • 8’6″ raised floor to underside of acoustical ceiling
    • 5 MW of total in-place capacity
    • 400kW – 1 MW capability per floor
    • Utility power in N+1 or custom 2N configuration
    • Generator power in N+1 or custom 2N configuration
    • Single and Redundant Power Feeds Available
    • 600 KW UPS N+1 configuration breaker power per floor with 7 minute full load battery backup
    • N+1 UPS power in a single or redundant feed configuration
    • Power Densities up to 200 Watts/sq. ft
    • Low power costs
    • Hot Aisle / Cold Aisle Configuration
    • N+1 chilled water system has the capacity of 1200 tons
    • Access to more than 15 different fiber carriers
    • Connectivity to 350 Cermak Road
    • Each tenant has an IDF on their floor with two 4″ conduits in redundant paths to building MMR
    Chicago Fiber Ring

    Chicago Fiber Ring

    • Air Side Economizer
    • Water Side Economizer
    • 18,000 sq. ft. ancillary / support / office space